Deep Foundations Testing. Cost-effective pile foundation system utilizing both the more traditional methods of inspection and new technology for a project. TWE has experience working with piling contractors and monitoring pile installation using the Pile Driving AnalyzerTM (PDA) in conjunction with the Case Pile Wave Analysis Program (CAPWAP) to evaluate static axialpile capacity and integrity. We specialize in providing complete driven pile deep foundation testing programs for projects of any scope and foundation type.
TWE also provides wave equation analysis (with GRLWEAP) to provide driveability studies, constructability analyses, and inspector charts to engineers and contractors in an effort to select the most efficient hammer systems and ensure proper driven pile installations.
Tolunay-Wong Engineers provides a full suite of deep
foundations testing services to clients throughout Texas and
Louisiana:
• Installation Monitoring
• Static Load Testing
• Instrumented Load Test
• Vibration Monitoring
• High-Strain Dynamic Testing Using PDA Equipment
• Low-Strain Dynamic Testing Using PIT Equipment
• Cross-Hole Sonic Logging
• Single-Hole Sonic Logging
• WEAP Analysis
• Driveability Analysis
• CAPWAP Analysis
• Thermal Integrity Profiling